24
Location Recorder Model PD606
Chapter 2: Preparation before using the PD606
<Note>:
When you use a battery with BMS (Battery Management System), you can check
the battery information via the "BATT. status" item in the "BATTERY SETUP" menu of
the MENU mode (see page 179).
Low battery warning setting
Whether you use a battery with or without BMS (Battery Management System), you
can set the threshold voltage for warning low battery.
When the battery voltage gets lower than the threshold voltage you set, the warning
tone is output from the headphones connected to the unit.
By default, the threshold voltage is set to 13.2V for battery with BMS or 13.0V for
battery without BMS. However, you can set the desired threshold voltage via the "BATT.
warning" item in the "BATTERY SETUP" menu of the MENU mode (see page 172).
Battery priority setting (essential when using more than one battery)
When you use two batteries or four PowerLink batteries, you must set the battery
priority (BATT1 or BATT2).
You can specify the battery to be used preferentially. When the preferential battery
gets empty, the display shows the warning popup window and the other battery auto-
matically takes over.
You can make setting via the quick setup mode or via the "Active battery" item in the
"BATTERY SETUP" menu of the MENU mode (see pages 77 and 175).
Important settings for using the battery
<Note>:
When you use a battery with BMS (Battery Management System), you can check
the remaining time until the battery voltage reaches the threshold voltage in one-minute
steps via the "BATT. Remain" item in the "BATTERY SETUP" menu of the MENU mode
(see page 178).
When you use PowerLink batteries, you
can mount up to four batteries (two bat-
teries for each base, as shown on the
right).
<Note>:
When you mount four batter-
ies, you cannot use the protector on the
bottom panel. Use the unit horizontally.
<Notes for using PowerLink batteries>
• When you use PowerLink batteries, use batteries of the same charging
condition. If the charging conditions are significantly different, the PowerLink
function may not operate correctly resulting the PD606 powered off.
• You cannot mount more than two batteries. Each battery mount can accept up
to two batteries.
<Note>:
While the battery has power, the output voltage is between 13 V to 15 V. When
the remaining power gets short, the output voltage rapidly drops. Therefore, to replace
the battery well in advance, we recommend setting the threshold voltage to 13 V or
around.
Summary of Contents for PD606
Page 1: ...LOCATION RECORDER Owner s Manual Model PD606...
Page 14: ...14 Location Recorder Model PD606 Introduction...
Page 15: ...15 Location Recorder Model PD606 Chapter 1 Main features Chapter 1 Main features...
Page 20: ...20 Location Recorder Model PD606 Chapter 1 Main features...
Page 72: ...72 Location Recorder Model PD606 Chapter 4 Basic connections...
Page 134: ...134 Location Recorder Model PD606 Chapter 7 Creating and editing ALE files EDIT EDL FILE menu...
Page 215: ...215 Location Recorder Model PD606 Chapter 9 Specifications Chapter 9 Specifications...
Page 225: ......