Bridge Hello Time
- Specifies the bridge hello time for the Common and Internal Spanning tree
(CST), with the value being less than or equal to "(Bridge Max Age / 2) - 1". The default hello time
value is 2.
Bridge Forward Delay
- Specifies the time spent in "Listening and Learning" mode before
forwarding packets. Bridge Forward Delay must be greater or equal to "(Bridge Max Age / 2) + 1".
The time range is from 4 seconds to 30 seconds. The default value is 15.
Spanning Tree Maximum Hops
- Configure the maximum number of hops for the Spanning tree.
Non-Configurable Data
Bridge identifier
- The bridge identifier for the CST. It is made up using the bridge priority and the
base MAC address of the bridge.
Time since topology change
- The time in seconds since the topology of the CST last changed.
Topology change count
- Number of times topology has changed for the CST.
Topology change
- The value of the topology change parameter for the switch indicating if a
topology change is in progress on any port assigned to the CST. It takes a value if True or False.
Designated root
- The bridge identifier of the root bridge. It is made up from the bridge priority and
the base MAC address of the bridge.
Root Path Cost
- Path Cost to the Designated Root for the CST.
Root Port
- Port to access the Designated Root for the CST.
Max Age
- Path Cost to the Designated Root for the CST.
Forward Delay
- Derived value of the Root Port Bridge Forward Delay parameter.
Hello Time
- Derived value of the Root Port Bridge Hello Time parameter.
Hold Time
- Minimum time between transmission of Configuration BPDUs.
CST Regional Root
- Priority and base MAC address of the CST Regional Root.
CST Path Cost
- Path Cost to the CST tree Regional Root.
Command Buttons
Submit
- Applies the new configuration and causes the changes to take effect. These changes will
not be retained across a power cycle unless a save configuration is performed.
Refresh
- Refreshes the screen with most recent data.
11.3.19.3 Configuring Spanning Tree MST Configuration Page