- 655 -
Configurable Data
Receiver Index
- The sFlowReceiver associated with this counter poller. Allowed range is (1 to 8 )
Poller Interval
- The maximum number of seconds between successive samples of the counters
associated with this data source. A sampling interval of 0 disables counter sampling. Allowed range
is (0 to 86400 secs)
Non-Configurable Data
Slot/Port
- The interface for which data is being displayed.
Receiver Index
- The sFlowReceiver for this sFlow Counter Poller. If set to 0, the poller
configuration is set to default and the poller is deleted. Only active receivers can be set. If a receiver
expires then all pollers associated with the receiver will also expire. Allowed range is (1 to 8 )
Poller Interval
- The maximum number of seconds between successive samples of the counters
associated with this data source.
Command Buttons
Submit
- Send the updated data to the switch and cause the changes to take effect on the switch.
Refresh
- Refresh the data on the screen with present state of data in the switch.
11.2.7.4 Configuring sFlow Sampler Configuration Page
sFlow agent collects statistical packet-based sampling of switched flows and sends them to the
configured receivers. A data source configured to collect flow samples is called a sampler.
Selection Criteria
sFlow Sampler Datasource(Slot/Port)
- sFlowDataSource for this flow sampler. This Agent will
support Physical ports only.
Configurable Data
Receiver Index
- The sFlow Receiver for this flow sampler. If set to 0, the sampler configuration is
set to default and the sampler is deleted. Only active receivers can be set. If a receiver expires then
all samplers associated with the receiver will also expire. Allowed range is (1 to 8 )
Sampling Rate
- The statistical sampling rate for packet sampling from this source. A sampling rate
of 1 counts all packets. A sampling rate of 0 disables sampling. Allowed range is (1024 to 65536 )
Maximum Header Size
- The maximum number of bytes that should be copied from a sampled
packet. Allowed range is (20 to 256 )
Non-Configurable Data
Summary of Contents for 548B
Page 1: ...FortiSwitch 548B Version 5 2 0 2 Administration Guide...
Page 492: ...492 Default Setting Decrement 10 Command Mode Interface Config...
Page 869: ...869...
Page 976: ...www fortinet com...