- 654 -
sFlow Receiver Timeout
- The time (in seconds) remaining before the sampler is released and
stops sampling. A management entity wanting to maintain control of the sampler is responsible for
setting a new value before the old one expires. Allowed range is (0 to 4294967295 secs) A value of
zero sets the selected receiver configuration to its default values.
sFlow Receiver Maximum Datagram Size
- The maximum number of data bytes that can be sent
in a single sample datagram. The manager should set this value to avoid fragmentation of the sFlow
datagrams. Default Value: 1400. Allowed range is (200 to 9116 )
sFlow Receiver Address
- The IP address of the sFlow collector. If set to 0.0.0.0 no sFlow
datagrams will be sent.
sFlow Receiver Port
- The destination port for sFlow datagrams. Allowed range is (1 to 65535 )
Non-Configurable Data
Receiver Index
- The index of this receiver.
Receiver Owner
- The entity making use of this sFlowRcvrTable entry. The empty string indicates
that the entry is currently unclaimed.
sFlow Receiver Timeout
- The time (in seconds) remaining before the sampler is released and
stops sampling.
sFlow Receiver Maximum Datagram Size
- The maximum number of data bytes that can be sent
in a single sample datagram.
sFlow Receiver Address
- The IP address of the sFlow collector.
sFlow Receiver Port
- The destination port for sFlow datagrams.
sFlow Receiver Datagram Version
- The version of sFlow datagrams that should be sent.
Command Buttons
Submit
- Send the updated data to the switch and cause the changes to take effect on the switch.
Refresh
- Refresh the data on the screen with present state of data in the switch.
11.2.7.3 Configuring sFlow Poller Configuration Page
sFlow agent collects time-based sampling of network interface statistics and sends them to the
configured sFlow receivers. A data source configured to collect counter samples is called a poller.
Selection Criteria
sFlow Poller Datasource(Slot/Port)
- sFlowDataSource for this sFlow sampler. This Agent will
support Physical ports only.
Summary of Contents for 548B
Page 1: ...FortiSwitch 548B Version 5 2 0 2 Administration Guide...
Page 492: ...492 Default Setting Decrement 10 Command Mode Interface Config...
Page 869: ...869...
Page 976: ...www fortinet com...