ISSUE
: 21/09/03
FD 6100 MAINTENANCE
MANUAL
REVISION
: 2.1
SECTION
: 01
PAGE 50
CONTENTS
4.3.6
FOLDING PLATES TEST
SUBJECT: Check the Folding plates management.
-
PROCEDURE:
-
Service CONTENTS access (see page 39) :
Press START key
and the UP key
, and keep pushing both keys while turning
the machine on.
Enter the access code:
SELECTION
, UP
, MEMORIZE
, DOWN
and START
-
Open the machine (see page 6).
-
Switch the top cover security ‘MACHINE-OPEN’ with a screwdriver in order to have no
risk to forget the shortcut of this security.
-
With the keyboard, select : ‘Advanced parameters’.
-
Select ‘Pocket life cycle’.
-
Press START
to begin the test cycle:
. Feeder A stop bar (selection between automatic and daily mode).
. Pocket A deflector (only for the European machines).
. Folding plate stopper cycle test.
- At the end of the test, don’t forget to remove the tool you have used to restore the top cover
security.