ISSUE
: 21/09/03
FD 6100 MAINTENANCE
MANUAL
REVISION
: 2.1
SECTION
: 01
PAGE 43
CONTENTS
4.3
FUNCTIONAL TESTS
4.3.1
ENVELOPE STOP POSITION
-
Remove the upper cover.
-
Check for presence of envelopes in the stacker.
-
Actuate the “AUTOSTART” detector with a piece of cardboard stiff enough and hold it
firmly in order to not be gripped between the drive rollers.
-
Start a manual cycle (holding the piece of cardboard).
-
Wait for the machine to stop, open it and with a fine pencil, mark the envelope along the
edge of the upper deflector (21PIC0028) while pushing up the top inserting plate, and
measure dimensions A. The A nominal value must be :
-
If the envelope height is
≤
105 mm (4,13 in.)
Æ
A = 6mm
±
3mm (0,23 in.
±
0,12
in.)
-
If the envelope height is
≥
152 mm (6 in.)
Æ
A = 10mm
±
3mm (0,39 in.
±
0,12 in.)
-
For the other envelopes
Æ
A = 8mm
±
3mm. (0,31 in.
±
0,12 in.)
UPPER DEFLECTOR
EDGE
TOP INSERTING
PLATE