![FOR-A MFR-16RUD Operation Manual Download Page 110](http://html1.mh-extra.com/html/for-a/mfr-16rud/mfr-16rud_operation-manual_2316666110.webp)
110
Storing Salvo Data to the Remote Control Unit (MFR-39RU/39RUA only)
Use a SALVO (RU STORE) button on the remote control panel as shown in the procedure
below.
(1) Assign a SALVO button on the remote control panel. Set the salvo for
RU STORE
.
► See section 5-4-3-12 “BTN ASSIGN.”
(2) Store salvo data as shown in the table below.
Step
Description
1
Press the SALVO button as shown below.
The button is highlighted and ready for
crosspoints to be assigned.
2
To assign crosspoints to a salvo, press
a destination button then a source button.
The selected buttons flash.
Repeat the procedure for all crosspoints.
3
MFR-39RU:
After completing the crosspoints assignments, press the SALVO button again.
The menu display appears as shown below.
MFR-39RUA:
After completing the crosspoints assignments, press the SALVO button again.
The Current DEST and SRC button displays change as shown below.
4
MFR-39RU:
To add crosspoints to an existing salvo, select a salvo number by turning the control
knob. Salvo numbers to which no crosspoints are assigned are indicated with (NEW).
Turn the control knob to select a number, and press the knob to confirm the selection.
MFR-39RUA:
Turn the control knob to select a number then press the control knob to confirm the
selection.
Executing Salvos
Use a SALVO (RU RECALL) button on the remote control panel as shown in the procedure
below.
(1) Assign a SALVO button on the remote control panel. Set the salvo for
RU RECALL
, and
select a Salvo number.
► See section 5-4-3-12 “BTN ASSIGN” and 5-5-2. "Button Assignment Change."
(2) Pressing the SALVO button to executes the salvo. The crosspoints stored to the salvo
number are simultaneously set.
SALVO STORE
NO: 1 (NEW) <ENT>