5-10. Setup Menu (Other Remote Control Units)
The
SETUP
button changes the RU to
Setup Menu
mode, which allows you to display RU and
MU PC-LAN network settings, reboot the MU PC-LAN port, and change the RU network settings
To exit Setup Menu mode, press the
SETUP
button again.
IP Address Display
The following procedure shows how to display an IP address in Setup Menu mode using
MFR-16RU as an example.
(1) Press
SETUP
. All idicators, POWER, BUSY and LOCK, turn on orange to indicate that the
RU enters in Setup Menu mode.
(2) Press Button
D
. (If Button
B
or
C
is lit, press the lit button.)
(3) Press the left-most button (the first octet) of Buttons
H
.
The first octet number will be displayed on Buttons
I
. If the MFR-16RU IP address is set to
"192.168.1.100," The eight buttons (8 bits) displays "192" (128+64) by turning the light
On
or
Off
for each bit (On, On, Off, Off, Off, Off, Off, Off).
(4) Press the second button (the second octet) of Buttons
H
.
The number value will be displayed on Buttons
I
.
If the MFR-16RU IP assress is set to "192.168.1.100," "168" will be displayed.
(5) Press the third button (the third octet) of Buttons
H
.
The number value will be displayed on Buttons
I
.
If the MFR-16RU IP assress is set to "192.168.1.100," "1" will be displayed.
(6) Press the right-most button (the fourth octet) of Buttons
H
.
The number value will be displayed on Buttons
I
.
If the MFR-16RU IP address is set to "192.168.1.100," "100" (64+32+4) will be displayed as
shown below (Off, On, On, Off, Off, On, Off, Off).
PAGE A
(HOLD 3SEC)
PAGE B
LOCK
RESET
POWER
BUSY
SETUP
LOCK DEST
(HOLD 3SEC)
LOCK PANL
A
B
REMOTE CONTROL UNIT
MFR-16RU
PAGE A
(HOLD 3SEC)
PAGE B
LOCK
RESET
POWER
BUSY
SETUP
LOCK DEST
(HOLD 3SEC)
LOCK PANL
A
B
REMOTE CONTROL UNIT
MFR-16RU
PAGE A
(HOLD 3SEC)
PAGE B
LOCK
RESET
POWER
BUSY
SETUP
LOCK DEST
(HOLD 3SEC)
LOCK PANL
A
B
REMOTE CONTROL UNIT
MFR-16RU