4-5. SETTINGS
1. MFR-LAN
[ IP ADDRESS ]
Step
Display
Description
1
Allows you to set the IP address.
(For MFR-LAN/LAN (TO RU) connection)
[ NET MASK ]
Step
Display
Description
1
Allows you to set the subnet mask.
(255.0.0.0 to 255.255.255.254)
(For MFR-LAN/LAN (TO RU) connection)
2. MU SETTING
[ MENU BRIGHTNESS ]
Step
Display
Description
1
Allows you to set the menu display
brightness.
brightness: 1 (dark) to 15 (bright)
[ REFERENCE ]
Step
Display
Description
1
Allows you to select how to select a
reference signal format.
AUTO: Automatic detection
MANUAL: Manual selection
If set to MANUAL, select a signal below.
2
Allows you to select a reference signal
from BB or TRI-SYNC.
[ FORMAT ]
Step
Display
Description
1
Allows you to select a video format
[ PS2 INSTALL ]
Step
Display
Description
1
Displays whether the redundant power
supply unit is present.
[ SHUT DOWN ]
Step
Display
Description
1
Allows you to select a slot to shut down.
2
Select OFF to shut down.
Select ON to supply power.
* When selecting the following functions, the confirmation display appears. (Select OK to
execute the function.)
■
CPU REDUNDANT:
Manually switches CPU cards 1 and 2.
Requires time for sharing files between CPUs after startup or
CPU changeover, during which crosspoint switchings cannot
be performed.
■
PC-LAN(IP ADDRESS INFO / NET MASK INFO / GATEWAY INFO):
Displays the PC-LAN port settings.
■
PC-LAN REBOOT:
Restarts the PC-LAN port.
I P 1 9 2 . 1 6 8 . 0 0 1 . 0
M A S K 2 5 5 . 2 5 5 . 0 0 0
B R I G H T 0 7
S L O T 0 1
P S 2 I N S T A L L E D
S L O T 0 1 O F F
R E F A U T O
R E F B B
F M T 1 0 8 0 5 9 . 9 4 i