![FOR-A MFR-16RUD Operation Manual Download Page 104](http://html1.mh-extra.com/html/for-a/mfr-16rud/mfr-16rud_operation-manual_2316666104.webp)
104
5-11-2. Enabling Multi-Panel Operation
Multi-panel operation can be enabled in the Setup menu or in the [Web-based Control:
RU
Settings
page].
The procedure to enable multi-panel operation in the Setup menu is as shown below.
(Supported only by MFR-39RU/39RUA)
MFR-39RUA
Step
Description
Refer to
1
Press SETUP to enter Setup menu.
2
Press
RU-RU CONNECT
.
3
Change
CONNECT
to ENABLE.
4
Turn the control knob to select a link ID under
MASTER ID
.
* The link ID is used to configure a link of multiple remote control units and
equal to the unit ID of the master unit in the remote control unit link. To
configure the remote control unit link using the master unit of Unit ID 100,
set
MASTER ID
to 100 for another remote control unit in the link system.
5
To exit Setup Menu mode, press EXIT twice.
MFR-39RU
Step
Description
1
Press the SETUP button to enter Setup menu.
2
Turn the control knob to select RU CONN ID, and press the knob to confirm.
Menu display
3
Turn the control knob to select the ID, and press the knob to confirm.
ID:
This ID is used to synchronize remote control panels for multi-panel operation. All
panels must have the same ID as the unit ID of the master remote control panel of the
system.
(ex.) To enable multi-panel operation using a master remote control panel whose unit
ID is 100, set the ID as 100 for all integrated remote control panels.
4
Press the CANCEL button to return the menu display to select menus. Turn the control
knob to select RU CONNECT, and press the knob to confirm.
Menu display
5
Turn the control knob to select ON, and press the knob to confirm.
Perform the above procedure for each remote control panel to be integrated.
To enable multi-panel operation in Web-based Control, proceed as follows:
(1) Click the remote control unit for setting to display the menu tree. Select
RU Settings
to
display the menu.
(2) Set the master remote control unit using Unit ID under
Master ID
(for RU Linkage).
(3) Set
RU Linkage
to ON.
SETUP>RU CONN ID
UNIT ID: 0<ENT>
SETUP>RU CONNECT
ENABLE:OFF<ENT>