Middle Position [Mid Pos]
Purpose:
The [Mid Pos] parameter determines the centre position of the
actuator spindle. An actuator stops at this position, if you press the
centre key
. In Automatic Operation this parameter has no
meaning.
Range:
0.0 to
300.0
Default: 62.5
5)
Increment:
0.1
Unit:
[mm]
5)
The default value is dependent on the used actuator
Condition:
This parameter appears on the display only if an actuator /
winderGLIDE is connected to the controller.
Maximal Position [Max Pos]
Purpose:
This parameter determines the limit for the extended position. In
Automatic Mode the actuator stops at this position and moves no
further forward. In Manual Operation this parameter has no
meaning.
Range:
0.0 to
300.0
Default: 125.0
5)
Increment:
0.1
Unit:
[mm]
5)
The default value is dependent on the used actuator
Condition:
This parameter appears on the display only if an actuator /
winderGLIDE is connected to the controller.