Operating Manual BKS309.MS
14.08.2018
17
In manual mode the frame will move to the left in 0.1mm steps by
pressing the button once. By pressing the button longer than 1 sec.
it will continuously move the frame to the left.
In automatic mode: Adjust Reference Position (left) is deactivated
for BKS309.MS.
In Setup-Position and independent if the device is in manual or automatic
mode, pressing the button increases continuously the parameter value.
In manual mode the frame will move to the right in 0.1mm steps by
pressing the button once. By pressing the button longer than 1 sec. it
will continuously move the frame to the right.
In automatic mode: Adjust Reference Position (right) is deactivated
for BKS309.MS
In Setup-Position and independent if the device is in manual or automatic
mode, pressing the button increases continuously the parameter value.
Note
If DLS (digital line sensors) are used, it may happen that the web guide controller
blocks the steering frame. This protective function is activated when the line is
interrupted and impossible to detect the line anymore. The LED above the
.key will start blinking and indicate to operator that the line quality is bad.
7.3
Automatic Operation
•
Start automatic mode with
key or digital input. Reference position is taken
from the middle of the sensor detection band (Fig. 12). Using center guide,
reference position is in the middle between the 2 sensor axis. The controller starts
to guide the web to reference position and to hold this guide point.
•
The reference position can be adjusted
during automatic operation by using the
•
keys or using digital inputs (step
width 0.1 mm). Using the key, the web
moves out of the sensor; using the
key, the web moves in Using center guide,
this description refers to the right sensor.
•
Terminate the automatic mode by using
the
key again.
Note
If the web leaves the sensor detection band, control is no longer effective. Hold
the web edge strictly inside the sensor detection band.
Fig. 12:
Position at automatic start
K
100005e