Operating Manual BKS309.MS
14.08.2018
28
Dead band [DeadBand]
Purpose:
This parameter defines the dead band tolerance. Dead band is a free
programmable range, in which the web may move freely without the
steering readjusting the frame. Keep in mind that: A [DeadBand] of
e.g. 0.3mm“ results in a tolerance band of ±0.3mm.
If the deviation is higher than the tolerance, the web will be readjusted into
the range of the dead band.
Range: 0.0
to
2.0
Default: 0.1
Increment:
0.1
Unit:
[mm]
Relay 1 or Relay 2 setting [Relay 1 or 2] (two Parameters one for each relay)
Purpose:
This parameter determines the relay behaviour.
The user can choose between seven settings.
Setting:
Middle Position [MidSenso]
Purpose:
If [MidSenso] is chosen then the relay goes on when the material
edge is at the sensor’s middle position.
(Default setting for Relay 1)
Setting:
Material Found [MatFound]
Purpose:
If [MatFound] is chosen then the relay goes on when material edge
is detected. (Default setting for Relay 2)
Setting:
Automatic Mode and Material Found [Auto&Mat]
Purpose:
If [Auto&Mat] is chosen then the relay goes on when material edge
is detected and the controller is in Automatic Operation.
Setting:
Automatic Mode and Material Missing [Aut&Miss]
Purpose:
If [Aut&Miss] is chosen then the relay goes on when no material
edge is detected and the controller is in Automatic Operation.
Setting:
Automatic Operation [Auto]
Purpose:
If [Auto] is chosen then the relay goes on when the controller is in
Automatic Operation.
Setting:
[Centre]
Purpose:
If [Centre] is chosen then the relay goes on as soon as the motor
drive stands still after a centre run.
Setting:
[Disabled]
Purpose:
If [Disabled] is chosen then the relay function is disabled. The relay
will never go on.