![FMS BKS309.MS Operating Manual Download Page 32](http://html1.mh-extra.com/html/fms/bks309-ms/bks309-ms_operating-manual_2313038032.webp)
Operating Manual BKS309.MS
14.08.2018
32
Language
Purpose:
This parameter determines the displayed language.
The user can choose between two languages.
Language:
[English]
Purpose: If
[English] is chosen, the display shows all texts in English. The web browser
is always in English.
Language:
[German]
Purpose:
If [German] is chosen, the display shows all texts in German.
LCD-Contrast [Contrast]
Purpose: The
parameter
[Contrast] changes the contrast of the LCD to achieve
optimal readability.
Range:
1 to
100
Default: 65
Increment:
1
Unit:
[%]
Unit System [Unit Sys]
Purpose:
This parameter determines the unit system used
.
The user can choose between two settings.
Setting:
[Metric]
Purpose:
If [Metric] is chosen, the controller displays all data in metric units.
Setting:
[Imperial]
Purpose:
If [Imperial]
is chosen, the controller shows all data in imperial
units.
Gain Setting [Gain]
Purpose:
This parameter defines the gain of the feed back value.
Range:
0.02 to
2.00
Default: 0.20
Increment:
0.01
Unit:
[ - ]