Operating Manual BKS309.MS
14.08.2018
27
8.6
Description Operation Parameter
Adjust Reference Position [Ref Pos]
Purpose:
The reference position can be adjusted using this parameter.
Range:
-5.00 to
+5.00
Default: 0.00
Increment:
0.01
Unit:
[mm]
Set Reference Mode [Ref Mode]
Purpose:
This parameter determinates how the reference position is defined.
This can either be the position that is defined with parameter [Ref
Pos] or the actual material position within the sensor when the
controller is switched to automatic operation.
Two settings are possible:
Setting:
[Manual]
Purpose:
If [Manual] is chosen, the Reference Position is taken from the
parameter [RefPos].
Setting:
Automatic [Auto]
Purpose: If
[Auto] behaviour is chosen, the Reference Position is determinate
by taking the actual material position within the sensor when the
controller is switched to automatic operation.
Save the Reference Position [SaveRef]
Purpose:
The parameter saves the last Reference Position change. It sets after
re-booting the Reference Position to the last used value or to 0 (zero).
Two settings are possible:
Setting:
[No]
Purpose:
If [No] behaviour is chosen, the Reference Position is set to 0 after
rebooting (default setting).
Setting:
[Yes]
Purpose: If
[Yes] behaviour is chosen, after rebooting the Reference Position is
set to the last used value.