Operating Manual BKS309.MS
14.08.2018
39
Centre Position [CentrPos]
Purpose: The
[CentrPos] parameter is only used with the position detection
system based on hall sensors. For all other position detection
system this parameter is not used and hence not displayed. The
parameter determines the centre position of the actuator spindle
in motor steps (measured from the left reference position). The
actuator stops at this position, if you press the centre key
.
In Automatic Operation this parameter has no meaning.
Right Limit [RightLim]
Purpose: The
[RightLim] parameter is only used with the position detection
system based on hall sensors. For all other position detection
system this parameter is not used and hence not displayed. The
parameter limits the maximum travel to the right side of the
actuator spindle in motor steps (measured from the left reference
position). In the operation or in manual mode this limit will never
be exceeded
Drive Direction [DriveDir]
Purpose:
This parameter determines the guiding orientation of the
controller.
This
parameter
should not be changed without contacting the
service department of FMS.
Setting:
[Standard]
Purpose:
[
Standard]
For standard motors and standard frames of FMS
(default setting).
Setting:
[Invers]
Purpose:
[
Invers] The controller sets the drive direction automatically, if
FMS products are use.