![FMS BKS309.MS Operating Manual Download Page 15](http://html1.mh-extra.com/html/fms/bks309-ms/bks309-ms_operating-manual_2313038015.webp)
Operating Manual BKS309.MS
14.08.2018
15
Caution
If the function “
Toggle between Manual and Automatic mode
” is controlled via the
digital inputs, the corresponding key
on the operation panel will be
deactivated.
Hardware access via screw terminals (see Fig. 9)
Signal Name
Terminal #
Dig.In 1
5
Dig.In 2
6
Dig.In 3
7
Dig.In 4
8
.
6.4
Differences between Standard and Master-Slave Electronics
Due to its use in the special field of chase & follow applications the BKS309.MS
Master-Slave unit has a slightly different parameter set if compared with the
standard web guide controller BKS309. Several functions aren’t any more available
with the BKS309.MS. Parameters connect to these functions are displayed and can
be modified without having any influence in the application. Following function are
not available in the BKS309.MS unit:
•
Reset of the frame reference position via digital inputs or the keys
and on
the operation panel.
•
Setting the Reference Value over the parameter [Ref Pos]
•
Determination of the Reference Position is deactivated and thus the parameter
[Ref Mod] has no impact. The Reference Position is always defined by the Master
Web Position.
•
A change of the Reference Position in automatic operation via the digital inputs or
via the web interface is not possible.