Operating Manual BKS309.MS
14.08.2018
38
8.7
Setting of System Parameters
Caution
System parameters are factory settings and should not be changed without contacting the
service department of FMS. An unauthorised change can cause malfunctions in the
system or damage in the machine.
To enter the System Parameter Setting Mode hold the two
+
keys for longer then
3 sec. The LED will light and the first parameter will appear on the LCD display
Offset Centre [Offset><]
Purpose:
This parameter adjusts the position of a steering frame exactly to
the centre.
Position Detection [PosDetec]
Purpose:
This parameter determines what devices that are used to detect the limit
positions.
The user can choose between three types.
Type:
[Potentio]
Purpose:
A potentiometer is used to detect the Home position, Middle
Position and Maximum Position. It is automatically set, if an
actuator / winderGLIDE of the type BKS.D.3 is used.
Type:
[One Hall]
Purpose:
One hall sensor is used to detect the Home position, Middle
Position and Maximum Position.
Type:
[Two Hall]
Purpose:
Two hall sensors are used to detect the Home position, Middle
Position and Maximum Position.