OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
7-24
Running the Test in Loopback Mode
W
Caution
If you disconnected the reference test cord from
the tester’s output, you must set the reference
again to ensure valid measurements.
1
Verify that the settings described in Table 7-1 are
appropriate. Let the tester warm up for 5 minutes.
2
Select Loss/Length mode: On the HOME screen, press
A
Change Test; then select Loss/Length.
3
Clean the connectors on the cabling to be tested.
4
Connect the tester to the cabling as shown in Figure
5
Press
T
to start the loss/length test.
6
To save the results, press
s
; select or create a fiber
ID; then press
s
again.
Loopback Mode Test Results
The SUMMARY screen, which appears when the test is
finished, is described in Table 7-6.
To see more detailed results, press
A
View Results. Table
7-7 describes the RESULTS screen.
Summary of Contents for OF-500-01 OptiFiber
Page 4: ......
Page 18: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook xiv...
Page 29: ...Getting Acquainted Powering the Tester 1 9 1 ajt20f eps Figure 1 1 Battery Pack Feature...
Page 31: ...Getting Acquainted Verifying Operation 1 11 1 ajt56f eps Figure 1 2 Removing the Module...
Page 48: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28...
Page 76: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 2 28...
Page 110: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 34...
Page 132: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 56...
Page 138: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6...
Page 144: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 5 6...
Page 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 44...
Page 216: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 10...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 12 30...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook A 2...
Page 268: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2...