Using the OTDR
Looking at OTDR Test Results
3-31
3
Table 3-4. Event Types (cont.)
The event is detected, but not enough information is available to measure its loss
separately from the previous event. Since the hidden event’s loss can’t be determined,
it is included with the loss of the previous event. This loss is displayed as "NA".
The hidden event may be a connection, a sharp bend, or a crack within the deadzone
of the previous connection.
If the event is not a connection, inspect the fiber near the event's location. Use a visual
fault locator to reveal faults.
Also see N/A in Table 3-3.
Caused by a dirty or unseated connector, highly-reflective connector, a connector with
the wrong polish, a sharp bend, or a crack in a fiber.
Find the GHOST SOURCE in the event table to determine where to look for the fault.
The ghost source is always before the ghost. The event table does not show ghosts
that occur after the end event.
If the ghost source is a hidden event, the tester may not identify a ghost event as a
ghost.
-continued-
Event
Possible Causes and Solutions
HIDDEN
The event is within the
attenuation deadzone of the
previous event.
GHOST
The event is a duplicate
reflection caused by light
bouncing back and forth
between connectors.
Summary of Contents for OF-500-01 OptiFiber
Page 4: ......
Page 18: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook xiv...
Page 29: ...Getting Acquainted Powering the Tester 1 9 1 ajt20f eps Figure 1 1 Battery Pack Feature...
Page 31: ...Getting Acquainted Verifying Operation 1 11 1 ajt56f eps Figure 1 2 Removing the Module...
Page 48: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28...
Page 76: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 2 28...
Page 110: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 34...
Page 132: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 56...
Page 138: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6...
Page 144: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 5 6...
Page 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 44...
Page 216: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 10...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 12 30...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook A 2...
Page 268: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2...