Table 3-7. Diagnosing Faults on OTDR Traces
-continued-
Large reflective event with high loss (top), excessive tailing (middle), or a hook on the falling
edge of the trace (bottom). May be identified as an end event though it occurs before the end of
the cabling. May be caused by the following:
•
A dirty, scratched, cracked, misaligned, or unseated connector. Misaligned or unseated
connectors can also cause large reflections that produce ghosts. Bad connectors should be
cleaned, repolished, or replaced. A hook, as shown in the bottom example, can occur when a
large reflection causes the OTDR detector’s gain to become non-linear.
•
A good connector with a sharp bend or crack within its deadzone. If the cable is tightly bent
the tester may indicate a break, especially at longer wavelengths or in Manual OTDR mode
with smaller resolution settings. Use a visual fault locator to precisely locate the fault.
•
A crack in the fiber. Use a visual fault locator to precisely locate the fault.
•
A connection between mismatched fibers (different backscatter coefficients, core sizes,
numerical apertures, or other parameters). The top example could be caused by a larger core
(on the left) connected to a smaller core.
Summary of Contents for OF-500-01 OptiFiber
Page 4: ......
Page 18: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook xiv...
Page 29: ...Getting Acquainted Powering the Tester 1 9 1 ajt20f eps Figure 1 1 Battery Pack Feature...
Page 31: ...Getting Acquainted Verifying Operation 1 11 1 ajt56f eps Figure 1 2 Removing the Module...
Page 48: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28...
Page 76: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 2 28...
Page 110: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 34...
Page 132: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 56...
Page 138: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6...
Page 144: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 5 6...
Page 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 44...
Page 216: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 10...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 12 30...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook A 2...
Page 268: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2...