Getting Started
Results within Accuracy Range
2
2-9
To change any of the settings shown in Table 2-3, proceed as follows:
1.
Turn the rotary switch to SETUP.
2.
If the setting you want to change is not on the first Setup screen, press
$
Page Down
to see additional Setup screens.
3.
Use
D U
to highlight the setting you want to change.
4.
Press
!
Choice
.
5.
Use
D U
to highlight the setting you want.
6.
Press
E
to store the highlighted setting.
7.
Repeat steps 2 through 6 to change additional settings.
Results within Accuracy Range
An asterisk following a test result value indicates that the value is within the test
tool’s range of accuracy, as shown in Figure 2-3. All tests except the wire map test
may produce results with an asterisk if required by the selected test standard.
If a “pass” result is marked with an asterisk, look for ways to improve the cable
installation to eliminate the marginal performance. A “fail” result marked with an
asterisk should be considered a failure.
The asterisk appears on displayed, uploaded, and printed test results.
Limit
Pass
Fail
Accuracy
Range of
Test Tool
*
Pass Region
*
Fail Region
oy02f.eps
Figure 2-3. The Asterisk and Test Tool Accuracy
Summary of Contents for CableAnalyzer DSP-4000 Series
Page 6: ...DSP 4000 Series Users Manual iv...
Page 8: ...DSP 4000 Series Users Manual vi...
Page 18: ...DSP 4000 Series Users Manual 1 8...
Page 60: ...DSP 4000 Series Users Manual 2 42...
Page 128: ...DSP 4000 Series Users Manual 6 6...
Page 160: ...DSP 4000 Series Users Manual 7 32...
Page 186: ...DSP 4000 Series Users Manual 8 26...
Page 188: ...DSP 4000 Series Users Manual...
Page 204: ...DSP 4000 Series Users Manual B 14 oy81f bmp Figure B 5 Autotest Report in Graphical Format...
Page 210: ...DSP 4000 Series Users Manual B 20...
Page 222: ...DSP 4000 Series Users Manual C 12...