DSP-4000 Series
Users Manual
8-18
Return Loss
Parameter
Specification
100 MHz
250 MHz
Frequency Range
1 MHz to 350 MHz
NA
NA
Step sizes
<31.4 MHz: 100 kHz
31.4 MHz to 100 MHz: 200 kHz
100 MHz to 350 MHz: 500 kHz
NA
NA
Amplitude Range
0 dB to 40 dB
NA
NA
Amplitude Resolution
0.1 dB
NA
NA
Directivity for
Baseline/Basic Link
27 - 7 log (f/100) dB, 1 MHz to 250 MHz;
30 dB maximum
27 dB
24.2 dB
Directivity for Permanent
Link and Channel
25 - 20 log (f/100) dB, 1 MHz to 250 MHz;
25 dB maximum
25 dB
17 dB
Tracking
0.5 dB, 1 MHz to 250 MHz
0.5 dB
0.5 dB
Source Match for
Baseline/Basic Link
20 dB, 1 MHz to 250 MHz
20 dB
20 dB
Source Match for
Permanent Link and
Channel
20 - 20 log (f/100) dB, 1 to 250 MHz;
20 dB maximum
20 dB
12 dB
Return Loss of Termination
for Baseline/Basic Link
20 - 15 log (f/100) dB, 1 MHz to 250 MHz;
25 dB maximum.
20 dB
14 dB
Return Loss of Termination
for Permanent Link and
Channel
16 - 15 log (f/100) dB, 1 MHz to 250 MHz;
25 dB maximum.
16 dB
10 dB
Note: Return Loss specifications apply to 100
Ω
cable only.
Summary of Contents for CableAnalyzer DSP-4000 Series
Page 6: ...DSP 4000 Series Users Manual iv...
Page 8: ...DSP 4000 Series Users Manual vi...
Page 18: ...DSP 4000 Series Users Manual 1 8...
Page 60: ...DSP 4000 Series Users Manual 2 42...
Page 128: ...DSP 4000 Series Users Manual 6 6...
Page 160: ...DSP 4000 Series Users Manual 7 32...
Page 186: ...DSP 4000 Series Users Manual 8 26...
Page 188: ...DSP 4000 Series Users Manual...
Page 204: ...DSP 4000 Series Users Manual B 14 oy81f bmp Figure B 5 Autotest Report in Graphical Format...
Page 210: ...DSP 4000 Series Users Manual B 20...
Page 222: ...DSP 4000 Series Users Manual C 12...