![Fluke CableAnalyzer DSP-4000 Series User Manual Download Page 182](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4000-series/cableanalyzer-dsp-4000-series_user-manual_2309835182.webp)
DSP-4000 Series
Users Manual
8-22
Power
Main unit and remote: NiMH battery pack, 7.2 V, 3500 mAh
Typical NiMH battery life: 8 to 10 hours
Charge time: 4 hours
AC adapter/charger, USA version: Linear power supply; 108 V ac to 132 V ac
input; 15 V dc, 1 A output
AC adapter/charger, international version: Switching power supply; 90 V ac to
264 V ac input; 15 V dc; 1 A output
Memory backup power in main unit: Lithium battery
Typical life of lithium battery: 5 years
Environmental Requirements
Operating temperature: 32
°
F to 113
°
F (0
°
C to 45
°
C)
Storage temperature: -4
°
F to +140
°
F (-20
°
C to +60
°
C)
Pollution degree: 2
Altitude: 6562 ft (2000 m)
Avoid use outside the operating boundaries shown in Figure 8-3.
Electromagnetic Compatibility
Emissions EN61326-1, Class A.
Immunity EN61326-1
Note: Exposure to a 3 V/m Rf field, in the range of 107 MHz – 148 MHz may
cause a maximum noise floor offset of +.62 dB above the calculated specification
of 1.5 dB.
Summary of Contents for CableAnalyzer DSP-4000 Series
Page 6: ...DSP 4000 Series Users Manual iv...
Page 8: ...DSP 4000 Series Users Manual vi...
Page 18: ...DSP 4000 Series Users Manual 1 8...
Page 60: ...DSP 4000 Series Users Manual 2 42...
Page 128: ...DSP 4000 Series Users Manual 6 6...
Page 160: ...DSP 4000 Series Users Manual 7 32...
Page 186: ...DSP 4000 Series Users Manual 8 26...
Page 188: ...DSP 4000 Series Users Manual...
Page 204: ...DSP 4000 Series Users Manual B 14 oy81f bmp Figure B 5 Autotest Report in Graphical Format...
Page 210: ...DSP 4000 Series Users Manual B 20...
Page 222: ...DSP 4000 Series Users Manual C 12...