![background image](http://html1.mh-extra.com/html/flow/94k-hyperpressure/94k-hyperpressure_manual_2307763049.webp)
8. Pry the seal carrier away from the end bell
using a small pry bar in the groove provided,
as shown.
Once the seal carrier is away from the end
bell, remove it by hand by sliding it along the
ceramic plunger.
Discard the used seal carrier, o-ring, and
high-pressure seal.
9. Repeat Steps 6–8 on the other end of the
intensifier.
10. Remove the shift sensors. Use the shift pin
tool to remove the shift pins. Refer to your
pump manual for detailed instructions.