22. Assemble the outlet components of the check valve
body. Thread the outlet adapter into the check valve
body. Secure hand tight.
23. Clean and inspect all surfaces in the end cap.
Lubricate the bore of the end cap with food grade
lubricant as shown.
CAUTION
Do NOT apply grease or lubricant to the conical
sealing surfaces. This can cause an inlet water leak.
Install the new check valve assembly by pushing it
into the end cap. Take care to align the check valve
assembly with the correct orientation as previously
noted in Step 6.
24. Remove the old anti-seize from the tie rods, nuts,
and washers.
25. Reinstall the end cap (complete with check valve
body assembly) by sliding the body along the tie rods
and guiding the high-pressure cylinder into the
bronze bushing of the end cap.
26. Reload the intensifier tie rods.
•
See
Maintenance Procedure A
, Assembling the
Intensifier
© Flow International Corporation
M-376 | 41
CHAPTER 3
Maintenance Procedures
Summary of Contents for 94K HYPERPRESSURE
Page 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Page 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...