10. Using the ratchet and socket, back off the tool nuts
exactly one
full turn.
CAUTION
Failure to properly back off the tool nuts will
make it impossible to remove the tool from the
tie rod, and could damage the intensifier.
11. Close the hand pump pressure-release valve by turn-
ing the valve handle clockwise until tight.
12. Pump the tool to the 9200 psi (634 bar) mark on the
pressure gauge.
Note:
It will take 60–70 pumps before pressure will
begin to build.
13. Wait 10 seconds, then recheck the gauge. If the nee-
dle falls off the mark, retighten the pump pressure
relief valve and bring pressure back up to the
9200 psi (634 bar) mark.
14. Loosen the four end cap nuts and back off
two
full
turns.
15. Bleed off the tool pressure by opening the pump
pressure-release valve.
16. Remove the hand pump hose from the tool at the
quick-disconnect fitting.
Note:
On some tool models the hand pump hose
does not have a quick-disconnect fitting. If this is the
case, leave the hose attached to the tool at all times
to prevent leaking.
17. Remove the pressure loading tool nuts and washers,
then remove the tool.
18. Remove the end cap nuts and washers.
22 | M-376
© Flow International Corporation
94K HYPERPRESSURE INTENSIFIER
Summary of Contents for 94K HYPERPRESSURE
Page 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Page 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...