13. Reinstall the check valve assembly and end cap to-
gether by sliding the end cap along the tie rods and
guiding the high-pressure cylinder into the bronze
bushing of the end cap. Take care to align the check
valve assembly with the correct orientation as previ-
ously noted in Step 5.
14. Reload the intensifier tie rods.
•
See
Maintenance Procedure A
, Assembling the
Intensifier
15. Reconnect the high-pressure tubing and the inlet
water hose.
26 | M-376
© Flow International Corporation
94K HYPERPRESSURE INTENSIFIER