7. Lay out and inspect all components of the outlet
check valve replacement kit.
8. Apply a small amount of Blue Lubricant to the
threads of the outlet adapter and insert the old spring
seat, new compression spring, and new outlet pop-
pet into the bore in the order shown.
9. Apply Blue Lubricant
to the surfaces of the
new outlet check valve
seat as shown and in-
sert it into the bore of
the check valve body.
Make sure the coned end is pointing out once in-
stalled, and that there is no Blue Lubricant on the
sealing face of the outlet check valve seat.
10. Thread the outlet adapter into the check valve body.
Torque to 200 ft-lb (271.2 N-m).
11. Reconnect the high-pressure tubing and the inlet wa-
ter hose.
© Flow International Corporation
M-376 | 45
CHAPTER 3
Maintenance Procedures
Summary of Contents for 94K HYPERPRESSURE
Page 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Page 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...