![background image](http://html1.mh-extra.com/html/flow/94k-hyperpressure/94k-hyperpressure_manual_2307763017.webp)
Maintenance Procedure A
Using the Pressure Loading Tool to Assemble and
Disassemble the Intensifier
Tools required
Pressure loading tool kit (042512-3)
½ in. drive torque wrench
½ in. drive ratchet
1
5
8
in. crow’s foot wrench (½ in. drive)
1
5
8
in. socket (½ in. drive)
1½ in. socket (½ in. drive)
1 in. open-end wrench
7
8
in. open-end wrench
13
16
in. open-end wrench
Food grade grease (A-4689)
Blue Lubricant (A-2185)
Anti-seize (A-10039)
The pressure loading tool
The following procedures use a special tool created especially for the
94K HyperPressure intensifier. You must read and understand these
usage notes before attempting any maintenance procedure that re-
quires the use of this tool. Failure to do so could damage the tool
and/or the component being serviced. Such damage is not covered
by warranty.
© Flow International Corporation
M-376 | 17
Summary of Contents for 94K HYPERPRESSURE
Page 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Page 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...