27. Torque the outlet adapter to 200 ft-lb (271.2 N-m).
Note
: The outlet adapter should be torqued on the
workbench, not when installed. Torquing when in-
stalled can disturb the sealing surface, and could
cause galling.
28. Reconnect the high-pressure tubing and the
inlet water hose.
42 | M-376
© Flow International Corporation
94K HYPERPRESSURE INTENSIFIER