![background image](http://html1.mh-extra.com/html/flow/94k-hyperpressure/94k-hyperpressure_manual_2307763048.webp)
014623-1 or -3 Long-block intensifier
(StoneCrafter)
020070-1 Short-block intensifier
(HyperPressure)
6. At one end of the intensifier, remove the end cap from
the tie rods. The check valve assembly will remain in
the end cap due to the compression of the o-ring on
the check valve body.
Note:
Unless check valve maintenance is necessary
(Maintenance Procedure D) it is not necessary to re-
move the check valve assembly from the end cap.
7. Remove the high-pressure cylinder and filler tube from
the intensifier end bell. Rocking the cylinder gently
while pulling outward is helpful in separating the cylin-
der from the end bell. When the cylinder is clear of
the end bell pull it straight out to avoid the ceramic
plunger.
48 | M-376
© Flow International Corporation
94K HYPERPRESSURE INTENSIFIER
Summary of Contents for 94K HYPERPRESSURE
Page 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Page 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...