44. Remove the intensifier from the assembly fixture and install on the
pump frame.
45. Lubricate the manifold o-rings (see illustration on Page 62) with food
grade grease and place them in the end bells. Bring the hydraulic
manifold and the intensifier together and secure them with the origi-
nal cap screws. Tighten the cap screws to 35 ft-lb (47 N-m).
If your intensifier does not connect directly to the hydraulic mani-
fold, simply replace the hydraulic lines. Take care to ensure proper
lubrication and placement of the o-rings.
Short-block (HyperPressure) intensifier ONLY
Reattach the intensifier to the plate removed in Step 11.
Procedure continues
46. Apply anti-seize to all threads of the
high-pressure tie rods and thread into
the nuts (hand tight).
47. Install shift pins and shift sensors. Refer to your pump
manual for detailed instructions.
© Flow International Corporation
M-376 | 59
CHAPTER 3
Maintenance Procedures
Summary of Contents for 94K HYPERPRESSURE
Page 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Page 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Page 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...