11. Loosen the screws that hold the manifold to
the intensifier, then separate the two assem-
blies. Drain oil from the intensifier ports.
If the intensifier is not connected to a hy-
draulic manifold, simply disconnect the hy-
draulic hose fittings from each end bell.
Short-block (HyperPressure)
intensifier only
After Step 11, remove the bolts from the
bottom of the intensifier so it will come off
the pump. The best approach is to remove
the two bolts on the top to remove the
plate, which makes it easier to access the
two bolts on the bottom.
014623-1 or -3 Long-block intensifier
(StoneCrafter)
020070-1 Short-block intensifier
(HyperPressure)
50 | M-376