321023
62
8.3.4.8
Service Test 8 - Freezer Performance Adjustment.
This test will allow the service technician to adjust the control performance points. Each step will
incrementally change the freezer performance warmer (towards 1) or colder towards (9) as adjusted.
The default value is 5.
•
The Refrigerator Temperature Up/Down keypads
/
are used to adjust the Performance
Offset value. WARMER (1 2 3 4
5
6 7 8 9) COLDER.
DEFAULT
COLDER
•
The last Freezer Performance Offset value displayed before leaving test 8 will be saved when
the refrigerator door(s) is closed.
8.3.5
Show Room Mode
A manual method to put the electronic control into a Show Room Mode has been provided. In this mode, the
control display and keypad will operate normally, but all all of the cooling and air moving devices will remain off.
The unit will remain in Show Room Mode until power is removed from the unit.
The Show Room Mode is set using the refrigerator display and keypad. Enter the Show Room Mode
by performing the following sequence of events:
1. Hold the fresh food compartment door light switch closed.
2. Press
the
FREEZER TEMPERATURE UP
keypad 3 times consecutively.
NOTE:
The three
keystrokes must be done consecutively within 10 seconds.
3. Release the fresh food compartment door light switch.
4. The control will display “S” in the freezer display and “H” in the fresh food compartment display to
confirm entry into Show Room Mode.
5. Entry to the Show Room Mode is confirmed by pressing the
FREEZER TEMPERATURE UP
keypad once more.
6. Once the Show Room Mode is confirmed, the display will return to a normal operating display with
set point values.
Summary of Contents for RX256DT4X1
Page 11: ...321023 11 2 3 Refrigerant Flow...
Page 12: ...321023 12 2 4 Cabinet Air Flow...
Page 13: ...321023 13 2 5 Ice And Water Dispenser Diagram...
Page 14: ...321023 14 2 6 Water Valve Diagram...
Page 15: ...321023 15 2 7 Typical External Sweat Pattern...
Page 16: ...321023 16 3 INSTALLATION...
Page 17: ...321023 17...
Page 18: ...321023 18...
Page 76: ...321023 76 Ice Water Dispensing Board...
Page 78: ...321023 78 Mid Electronic Specification Control RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 104: ...321023 104 14 WIRING DIAGRAMS 14 1 Wiring Schematic RX256DT7X1...
Page 105: ...321023 105 14 2 Wiring Diagram RX256DT7X1...
Page 106: ...321023 106 14 3 Wiring Schematic RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 107: ...321023 107 14 4 Wiring Diagram RX256DT4X1 RX256ET2B1 RX256ET2W1...
Page 108: ...321023 108 NOTES...