83
Appendix Q: - Operation Result Reading Commands
Operation result reading command format as below: -
a.
Start String
*
“asterisk” (Hex code 02A), followed by
b.
Command code as shown on below table (all commands are case sensitive), followed by
c.
End String
#
“number sign” (Hex code 23).
Notes: -
For RS485 communication, add @xx before start string.
xx = machine ID number set in F18.
Command Description Table
Command Definition
Command Format
Parameter
Output
Parameter Description
Start
String
Command Code
(Note D)
End
String
Read Current Tare Weight
*
R0 or R1 or R2 or RA
CWTA
#
d1
8 digits including decimal
Read Current Gross Weight
*
R0 or R1 or R2 or RA
CWGS
#
d1
8 digits including decimal (if any)
Read Current Net Weight
*
R0 or R1 or R2 or RA
CWNT
#
d1
8 digits including decimal (if any)
Read Weight Unit of Current Net,
Tare and Gross Weight
*
R0 or R1 or R2 or RA
CWUN
#
d1
8 digits including decimal (if any)
Read Qty Value
*
R0 or R1 or R2 or RA
CQTY
#
d1
8 digits
Read Low Limit
*
R0 or R1 or R2 or RA
CHKL
#
d1
8 digits including decimal (if any)
Read High Limit
*
R0 or R1 or R2 or RA
CHKH
#
d1
8 digits including decimal (if any)
Read Check Target
*
R0 or R1 or R2 or RA
CHKT
#
d1
kg = kilogram, (space)g = gram,
pcs = quantity
Read Check Result
*
R0 or R1 or R2 or RA
CHKR
#
d1
Below/Accept/Above