background image

Model: SD1110

Rechargeable  

Portion Control Scale 

11 pounds/5 kilograms/176 ounces  

by pounds:ounces, ounces, fractional ounces and grams

Features

• Submersible
• Programmable
• Tare function
• Backlit display
• Field calibration
• Low/high limit alerts
• Stainless steel housing
• Removable stainless steel platform
• Rechargeable battery
• Power adapter
• Stability indication
• Selectable units
• Overload indication
• Battery status indication
• On/off button
• Auto-off after 2 minutes

Note:

 In the following instructions, names of the control 

buttons are shown in CAPS. Function information that 

appears on the display is shown in 

BOLD CAPS

.

Charging the Battery

The 

LOW BATTERY

 icon ( ) appears on the display 

when battery status is low and needs to be charged. 
The battery is built-in and does not need to be 
replaced.
1. Insert the adapter plug into the jack on the back  

of the scale. Allow the scale to charge for 5 hours.  
The scale will then operate continuously for 
approximately 14 hours

Operating Instructions

Place the scale gently on a hard and flat surface and 
make sure it is steady before use to obtain accurate 
measurements.

A. On/Off

1. Press the POWER button ( ) to turn on. The display 

flashes all segments and then returns to zero. 

2. The 

STABILITY icon ( )

 appears in the lower left 

corner of the display when the weight is stable.

3. Press the POWER button ( ) to turn off.

B. Auto Off 

The scale automatically turns off after 2 minutes 
of inactivity.

C. Backlit Display 

Press and hold the UNIT button for 3 seconds to 
turn the backlit display on and off. 

D. Unit Selection

1. Press the UNIT button to select the desired unit. 

The display cycles through 

g

lb

:

oz

lb

:/

oz

lb

oz

and /

oz

2. Press the SET button to confirm and return to 

weighing mode.

Summary of Contents for SD1110

Page 1: ...in and does not need to be replaced 1 Insert the adapter plug into the jack on the back of the scale Allow the scale to charge for 5 hours The scale will then operate continuously for approximately 14 hours Operating Instructions Place the scale gently on a hard and flat surface and make sure it is steady before use to obtain accurate measurements A On Off 1 Press the POWER button to turn on The d...

Page 2: ... before automatically turning off The calibration is complete H Battery Status Low Battery Battery status is low and needs to be charged See Charging the Battery on page 1 I Error Messages oL indicates an overload when the item being measured exceeds the capacity of the scale Immediately remove the overweight item to avoid causing permanent damage to your scale J Programmable Modes The scale has b...

Page 3: ...F appears on the display 7 Press the SET button to confirm the selection GrAu appears on the display 8 Press the UNIT button END appears on the display 9 Press the SET button to save the settings and return to weighing mode b Gravity Compensation Value Editing Contact CDN for the value to enter for your location Note Gravity compensation must be disabled for this value to take effect 1 Press and h...

Page 4: ...ic discharge or malfunctioning occurs please re install the battery to reset this unit 10 2016 Component Design Northwest Inc Made in China CD9999319en 10 16 L DESIGN 614 525 1472 The information in this document has been reviewed and is believed to be accurate However neither the manufacturer nor its affiliates assume any responsibility for inaccuracies errors or omissions that may be contained h...

Reviews: