background image

PRECAUTIONS

• Keep the scale and/or adapter away from children.
• Do not clean the scale with abrasive or corrosive 

compounds, which may scratch the surface and 
corrode the electronic circuits.

• Do not subject the scale to excessive force, shock, 

dust, temperature or humidity, which may result in 
malfunction, shorter electronic life span, damaged 
battery and/or distorted parts.

• Do not tamper with the scale’s internal components. 

Doing so will invalidate the warranty and may cause 
unnecessary battery damage and/or distorted parts.

• Do not subject the scale to excessive exposure to 

direct sunlight. 

• 

IP67

 — protected from water up to 3 feet for  

30 minutes, completely protected against dust.

• Always read the users manual thoroughly  

before operating.

Specifications

Measurement Range

11 lbs/176 oz/5000 g

Unit of Measure

lb/oz/g

Resolution

 

0.1 oz, 1/8 oz, 0.005 lb, 0.05 oz, 1/8 oz, 1 g

Operating Range

32°F~104°F/0°C~40°C/≤90% RH

Accuracy

2000g ± 6g ; 5000g ± 15g

Power Supply

4.8V 1800mAH built-in rechargeable battery;  

AC Adapter: 100-240VAC 50/60Hz input, 9V DC 

(1000mA) output

Dimensions

7.32 W x 9.625 H x 2.125 D (inches)/ 

18.6 W x 24.4 H x 5.4 D (mm)

Weight

62 oz / 1760 g

Accessories

AC Adapter (AD-AC1110) 

Removable stainless steel platform  

(AD-PF1110) 

5 kg calibration weight (WT05)

CE Note: 

This device could be sensitive to electrostatic 

discharge. If electrostatic discharge or malfunctioning 

occurs, please re-install the battery to reset this unit.

© 10-2016 Component Design Northwest, Inc. 

Made in China 

CD9999319en - 10/16   L-DESIGN 614.525.1472

The information in this document has been reviewed 

and is believed to be accurate. However, neither the 

manufacturer nor its affiliates assume any responsibility 

for inaccuracies, errors or omissions that may be 

contained herein. In no event will the manufacturer or its 

affiliates be liable for direct, indirect, special, incidental 

or consequential damages arisen by using this product 

or resulting from any defect/omission in this document, 

even if advised of the possibility of such damages. 

 

The manufacturer and its affiliates reserve the right to 

make improvements or changes to this document and the 

products and services described at any time, without notice 

or obligation.

1-Year Limited Warranty: 

Any instrument that 

proves to be defective in material or workmanship 

(excluding batteries) within one year of original 

purchase will be repaired or replaced without 

charge upon receipt of the unit prepaid at: 

CDN, PO Box 10947, Portland, OR 97296-0947 

USA. This warranty does not cover damage in 

shipment or failure caused by failure to adhere 

to the accompanying instructions, inadequate 

maintenance, normal wear and tear, tampering, 

accident, misuse, unauthorized modification, 

obvious carelessness or abuse. CDN shall not  

be liable for any consequential or incidental 

damages whatsoever.

For more detailed  
information on our  
products, please visit  
CDNkitchen.com.

Summary of Contents for SD1110

Page 1: ...in and does not need to be replaced 1 Insert the adapter plug into the jack on the back of the scale Allow the scale to charge for 5 hours The scale will then operate continuously for approximately 14 hours Operating Instructions Place the scale gently on a hard and flat surface and make sure it is steady before use to obtain accurate measurements A On Off 1 Press the POWER button to turn on The d...

Page 2: ... before automatically turning off The calibration is complete H Battery Status Low Battery Battery status is low and needs to be charged See Charging the Battery on page 1 I Error Messages oL indicates an overload when the item being measured exceeds the capacity of the scale Immediately remove the overweight item to avoid causing permanent damage to your scale J Programmable Modes The scale has b...

Page 3: ...F appears on the display 7 Press the SET button to confirm the selection GrAu appears on the display 8 Press the UNIT button END appears on the display 9 Press the SET button to save the settings and return to weighing mode b Gravity Compensation Value Editing Contact CDN for the value to enter for your location Note Gravity compensation must be disabled for this value to take effect 1 Press and h...

Page 4: ...ic discharge or malfunctioning occurs please re install the battery to reset this unit 10 2016 Component Design Northwest Inc Made in China CD9999319en 10 16 L DESIGN 614 525 1472 The information in this document has been reviewed and is believed to be accurate However neither the manufacturer nor its affiliates assume any responsibility for inaccuracies errors or omissions that may be contained h...

Reviews: