23
confIguratIon
25.
Outputs orientation
Only in Double Switch Mode
Description
This parameter allows reversing the operation
of Q1 and Q2 without changing the wiring (e.g.
in case of invalid connection). Changing orienta-
tion turns both outputs off.
Parameter size
1B
Default value
0
Available
values
0 – default (Q1 - 1st channel, Q2 - 2nd channel)
1 – reversed (Q1 - 2nd channel, Q2 - 1st channel)
30.
Alarm configuration - 1st slot
Description
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
Parameter size
4B
Default value
[0x00, 0x00, 0x00, 0x00] (disabled)
Available
values
1B
[MSB] – Notification Type
2B
– Notification Status
3B
– Event/State Parameters
4B
[LSB] – action:
0x00
– no action,
0xX1
– turn ON,
0xX2
– turn
OFF,
0xX3
– turn ON/OFF continuously,
0x0X
– no action on LED frame,
0x1X
– LED frame
blinks red,
0x2X
– LED frame blinks green,
0x4X
– LED frame blinks blue,
0x8X
– disable
LED frame,
0xFX
– LED frame LAPD signal
(red-white-blue)
31.
Alarm configuration - 2nd slot
Description
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
Parameter size
4B
Default value
[0x05, 0xFF, 0x00, 0x00]
(Water Alarm, any notification, no action)