29
confIguratIon
150.
First channel – operating mode
Description
This parameter allows to choose operating for
the 1st channel .
Parameter size
1B
Default value
0
Available
values
0 – standard operation
1 – delayed OFF
2 – single pulse
151.
Second channel – operating mode
Only in Double Switch Mode
Description
This parameter allows to choose operating for
the 2nd channel.
Parameter size
1B
Default value
0
Available
values
0 – standard operation
1 – delayed OFF
2 – single pulse
152.
First channel - reaction to switch for delayed OFF /
pulse modes
Description
This parameter determines how the device in
timed mode reacts to pushing the button for 1st
channel.
The parameter is relevant only for button tog-
gles modes (parameter 20 set to 1 or 3).
Parameter size
1B
Default value
0
Available
values
0 – cancel mode and set default state
1 – no reaction - mode runs until it ends
2 – reset timer - start counting from the
beginning