27
confIguratIon
61.
Power reports for first channel – on change
Description
This parameter defines minimal change (from
the last reported) in measured power that re-
sults in sending new report. For loads under
50W the parameter is irrelevant, report are sent
every 5W change.
Parameter size
2B
Default value
15 (15%)
Available
values
0 – reporting on change disabled
1-500 (1-500%, 1% step) – minimal change
62.
Power reports for first channel – periodic
Description
This parameter defines reporting interval for
measured power. Periodic reports are indepen-
dent from changes in value (parameter 61).
Parameter size
2B
Default value
3600 (1h)
Available
values
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval
63.
Power reports for second channel – on change
Only in Double Switch Mode
Description
This parameter defines minimal change (from
the last reported) in measured power that re-
sults in sending new report. For loads under
50W the parameter is irrelevant, report are sent
every 5W change.
Parameter size
2B
Default value
15 (15%)
Available
values
0 – reporting on change disabled
1-500 (1-500%, 1% step) – minimal change
64.
Power reports for second channel – periodic
Only in Double Switch Mode
Description
This parameter defines reporting interval for
measured power. Periodic reports are indepen-
dent from changes in value (parameter 63).
Parameter size
2B
Default value
3600 (1h)