35
Z-Wave specIfIcatIon
Notification Command Class
The device uses Notification Command Class to report different
events to the controller (“Lifeline” group).
Notification
Type
Event
Parameter
In endpoints
Power Manage-
ment [0x08]
Over-current
detected
[0x06/V3]
Root, Endpoint
1, Endpoint 2*
Power Manage-
ment [0x08]
Over-load de-
tected [0x08]
Root, Endpoint
1, Endpoint 2*
System [0x09]
System hard-
ware failure with
manufacturer
proprietary fail-
ure code [0x03]
MP code: 0x01
[device
overheat]
Only Root
Protection CC
Protection Command Class allows to prevent local or remote control
of the outputs.
Type State
Description
Hint
Local
0
Unprotected - The device is not
protected, and may be operated
normally via the user interface.
Inputs connected
with outputs.
Local
2
No operation possible – button
can not change relay state, any
other functionality is available
(menu).
Inputs discon-
nected from
outputs.
RF
0
Unprotected - The device accept
and respond to all RF Commands.
Outputs can be
controlled via
Z-Wave.
RF
1
No RF control – command class ba-
sic and switch binary are rejected,
every other command class will be
handled.
Outputs cannot
be controlled via
Z-Wave.