6
specIfIcatIons
3: Specifications
Power supply
110-230V~ 50/60 Hz
Rated load current
13A per one channel
16A total
Compatible load types
incandescent bulbs
tube lamps
electronic transformers
ferromagnetic transformers
LED
Active element
micro-gap relay μ
Recommended external
overcurrent protection
10A type B circuit breaker (EU)
13A type B circuit breaker (Sweden)
For installation in boxes
Ø = 60mm, depth ≥ 40mm
Operating temperature
0–35°C
Ambient humidity
10–95% RH without condensation
Radio protocol
Z-Wave (500 series chip)
Radio frequency
868.4 or 869.8 MHz EU;
869.0 MHz RU;
Transmit power
EIRP max. 6dBm
Range
up to 50m outdoors
up to 40m indoors
(depending on terrain and building
structure)
Dimensions
(Height x Width x Depth)
86 x 86 x 51 mm
Compliance with EU
directives
RoHS 2011/65/EU
RED 2014/53/EU
i
Radio frequency of individual device must be same as
your Z-Wave controller. Check information on the box
or consult your dealer if you are not sure.