24
confIguratIon
Available
values
1B
[MSB] – Notification Type
2B
– Notification Status
3B
– Event/State Parameters
4B
[LSB] – action:
0x00
– no action,
0xX1
– turn ON,
0xX2
– turn
OFF,
0xX3
– turn ON/OFF continuously,
0x0X
– no action on LED frame,
0x1X
– LED frame
blinks red,
0x2X
– LED frame blinks green,
0x4X
– LED frame blinks blue,
0x8X
– disable
LED frame,
0xFX
– LED frame LAPD signal
(red-white-blue)
32.
Alarm configuration - 3rd slot
Description
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
Parameter size
4B
Default value
[0x01, 0xFF, 0x00, 0x00]
(Smoke Alarm, any notification, no action)
Available
values
1B
[MSB] – Notification Type
2B
– Notification Status
3B
– Event/State Parameters
4B
[LSB] – action:
0x00
– no action,
0xX1
– turn ON,
0xX2
– turn
OFF,
0xX3
– turn ON/OFF continuously,
0x0X
– no action on LED frame,
0x1X
– LED frame
blinks red,
0x2X
– LED frame blinks green,
0x4X
– LED frame blinks blue,
0x8X
– disable
LED frame,
0xFX
– LED frame LAPD signal
(red-white-blue)
33.
Alarm configuration - 4th slot
Description
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
Parameter size
4B
Default value
[0x02, 0xFF, 0x00, 0x00]
(CO Alarm, any notification, no action)