20
confIguratIon
3.
Second channel – overload safety switch
Only in Double Switch Mode
Description
This function allows to turn off the controlled
device in case of exceeding the defined power.
Controlled device can be turned back on via
button or sending a control frame.
Parameter size
4B
Default value
0 (disabled)
Available
values
0 – function disabled
10-36200 (1.0-3620.0W, step 0.1W) – power
threshold
10.
LED frame – power limit
Description
This parameter determines maximum active
power. Exceeding it results in the LED frame
flashing violet. Function is active only when pa-
rameter 11 is set to 8 or 9.
Parameter size
4B
Single Switch Mode
Default value
36800 (3680W)
Available
values
500-36800 (50.0-3680.0W, step 0.1W) – power
threshold
Double Switch Mode
Default value
30000 (3000W)
Available
values
500-30000 (50.0-3000.0W, step 0.1W) – power
threshold