3. Installation
3-10
Festo P.BE-VTSA-44-EN en 1101f
Disconnecting
Proceed as follows:
Warning
If the pneumatic tubing is under pressure when dis-
mounted, it may perform sudden unexpected movements,
causing injury to persons. Carry out the following steps
before disconnecting the pneumatic tubing on the valve
terminal:
•
Switch off the compressed air supply.
•
Make sure that all pneumatic tubing is unpressurized.
•
Exhaust all actuators controlled by valves that are
blocked in the rest or middle positions.
1. Mark all pneumatic tubing.
2. Depending on connection:
–
Press down the locking ring of the threaded con-
nector
1
, e.g. with a screwdriver or Festo QSO
releasing tool.
–
Loosen the clamping screw
2
of the threaded
connector.
–
Loosen the hose clamp screw
3
.
3. Remove the tubing from the threaded connector.
4. Seal threaded connectors that are not required with
blanking plugs
4
.
Summary of Contents for VTSA-44-ASI Series
Page 2: ......
Page 16: ...Contents and general instructions XIV Festo P BE VTSA 44 EN en 1101f ...
Page 17: ...Summary of components 1 1 Festo P BE VTSA 44 EN en 1101f Chapter 1 Summary of components ...
Page 63: ...Fitting 2 1 Festo P BE VTSA 44 EN en 1101f Chapter 2 Fitting ...
Page 79: ...Installation 3 1 Festo P BE VTSA 44 EN en 1101f Chapter 3 Installation ...
Page 89: ...3 Installation 3 11 Festo P BE VTSA 44 EN en 1101f 1 2 4 3 Fig 3 2 Removing the tubing ...
Page 125: ...Commissioning 4 1 Festo P BE VTSA 44 EN en 1101f Chapter 4 Commissioning ...
Page 142: ...4 Commissioning 4 18 Festo P BE VTSA 44 EN en 1101f ...
Page 167: ...Technical appendix A 1 Festo P BE VTSA 44 EN en 1101f Appendix A Technical appendix ...
Page 210: ...B Supplementary component summary B 18 Festo P BE VTSA 44 EN en 1101f ...
Page 211: ...Index C 1 Festo P BE VTSA 44 EN en 1101f Appendix C Index ...
Page 212: ...C Index C 2 Festo P BE VTSA 44 EN en 1101f Contents C Stichwortverzeichnis C 1 ...
Page 220: ...C Index C 10 Festo P BE VTSA 44 EN en 1101f ...