1. Summary of components
1-6
Festo P.BE-VTSA-44-EN en 1101f
VTSA with multi-pin
plug connection
Sub-D
Cage
Clamp
M23
round plug
Individual con-
nection (IC)
1) 2)
Maximum number of solenoid coils
which can be actuated
32
32
16
20 (12)
Manifold
sub-base type
Width [mm]
Number of valve positions
3)
1 controllable coil
per valve position
– VABV...-2
T1
– VABV...-
T1
18 or 26
42 or 52
2, 4, 6 ... 32
1, 2, 3 ... 32
2, 4, 6 ... 32
1, 2, 3 ... 32
2, 4, 6 ... 16
1, 2, 3 ... 16
2, 4, 6 ... 20 (12)
1, 2, 3 ... 20 (12)
2 controllable coils
per valve position
– VABV...-2
T2
– VABV...-
T2
18 or 26
42 or 52
2, 4, 6 ... 16
1, 2, 3 ... 16
2, 4, 6 ... 16
1, 2, 3 ... 16
2, 4, 6 ... 8
1, 2, 3 ... 8
2, 4, 6 ... 10 (6)
1, 2, 3 ... 10 (6)
1)
Multi-pin IC with 10 or 6 individual connections Per individual connection, 2 solenoid coils can be
connected.
2)
Specification in parentheses (12) or (6) for IC with 6 individual connections.
3)
The maximum number of valve positions does not apply in the case of mixed components of a
valve terminal with manifold sub-bases T1
and
T2.
Tab. 1/3:
Number of valve positions for VTSA... with multi-pin plug connection
VTSA with AS interface type
VTSA-4E4A-Z
VTSA-8E8A-Z
Maximum number of solenoid coils which can be actuated
4
8
Type of manifold sub-bases
Width [mm]
Number of valve positions
1)
1 controllable coil per valve position
– VABV...-2
T1
– VABV...-
T1
18 or 26
42 or 52
2 or 4
1, 2, 3 ... 4
2, 4, 6 ... 8
1, 2, 3 ... 8
2 controllable coils per valve position
– VABV...-2
T2
– VABV...-
T2
18 or 26
42 or 52
2
1 or 2
2 or 4
1, 2, 3 ... 4
1)
The maximum number of valve positions does not apply in the case of mixed components of a
valve terminal with manifold sub-bases T1
and
T2.
Tab. 1/4:
Number of valve positions for VTSA... with AS-interface
Summary of Contents for VTSA-44-ASI Series
Page 2: ......
Page 16: ...Contents and general instructions XIV Festo P BE VTSA 44 EN en 1101f ...
Page 17: ...Summary of components 1 1 Festo P BE VTSA 44 EN en 1101f Chapter 1 Summary of components ...
Page 63: ...Fitting 2 1 Festo P BE VTSA 44 EN en 1101f Chapter 2 Fitting ...
Page 79: ...Installation 3 1 Festo P BE VTSA 44 EN en 1101f Chapter 3 Installation ...
Page 89: ...3 Installation 3 11 Festo P BE VTSA 44 EN en 1101f 1 2 4 3 Fig 3 2 Removing the tubing ...
Page 125: ...Commissioning 4 1 Festo P BE VTSA 44 EN en 1101f Chapter 4 Commissioning ...
Page 142: ...4 Commissioning 4 18 Festo P BE VTSA 44 EN en 1101f ...
Page 167: ...Technical appendix A 1 Festo P BE VTSA 44 EN en 1101f Appendix A Technical appendix ...
Page 210: ...B Supplementary component summary B 18 Festo P BE VTSA 44 EN en 1101f ...
Page 211: ...Index C 1 Festo P BE VTSA 44 EN en 1101f Appendix C Index ...
Page 212: ...C Index C 2 Festo P BE VTSA 44 EN en 1101f Contents C Stichwortverzeichnis C 1 ...
Page 220: ...C Index C 10 Festo P BE VTSA 44 EN en 1101f ...