3. Installation
3-32
Festo P.BE-VTSA-44-EN en 1101f
Valve sub-bases
Pressure zone with vacuum or
low pressure supply via
connection (1)
The pressure zone must be fitted only with the following valve
sub-bases:
– 5/2-way valve, monostable (ident. code M and O)
– 5/2-way double pilot valve (ident. code J and D)
– 5/3-way valves (ident. code G, E and B)
– Reversible 3/2-way valve (ident. code P, Q and R).
These valves must be operated via port (3) and (5)
in a separate pressure zone with vacuum or low pressure.
Valves with ident. code K, H, and N (2x3/2-way valves) with supply
through port (1) are
not
suitable for vacuum or low pressure.
Pressure zone with excess
pressure supply
1)
via port (1)
The pressure zone can be fitted additionally with the following
valve sub-bases:
– 2x2/2-way valves (ident. code VC and VV), see also
the following note
– 2x3/2-way valves (ident. code K,H and N)
1)
in accordance with diagrams in Appendix A, Fig. A/1
Tab. 3/3:
Valve sub-bases
Note
Reversible 2x2/2-way valve with ident. code VV:
– If the VTSA/VTSA-F valve terminal is also equipped with
other valves, operate the reversible 2/2-way valve in a
separate pressure zone with separate exhaust ducts.
Connecting the valve in vacuum operation:
– Supply operating pressure for the pneumatic springs at
port (1).
– Either supply vacuum at port (5) and operating pressure
at port (3) or vice versa.
– The suction line (line supplied with vacuum) shall be
equipped with a filter to prevent any contamination from
entering into the valve.
– In vacuum operation, the suction line and the pressure
line shall be connected via a T-piece for the ejector
pulse.
Summary of Contents for VTSA-44-ASI Series
Page 2: ......
Page 16: ...Contents and general instructions XIV Festo P BE VTSA 44 EN en 1101f ...
Page 17: ...Summary of components 1 1 Festo P BE VTSA 44 EN en 1101f Chapter 1 Summary of components ...
Page 63: ...Fitting 2 1 Festo P BE VTSA 44 EN en 1101f Chapter 2 Fitting ...
Page 79: ...Installation 3 1 Festo P BE VTSA 44 EN en 1101f Chapter 3 Installation ...
Page 89: ...3 Installation 3 11 Festo P BE VTSA 44 EN en 1101f 1 2 4 3 Fig 3 2 Removing the tubing ...
Page 125: ...Commissioning 4 1 Festo P BE VTSA 44 EN en 1101f Chapter 4 Commissioning ...
Page 142: ...4 Commissioning 4 18 Festo P BE VTSA 44 EN en 1101f ...
Page 167: ...Technical appendix A 1 Festo P BE VTSA 44 EN en 1101f Appendix A Technical appendix ...
Page 210: ...B Supplementary component summary B 18 Festo P BE VTSA 44 EN en 1101f ...
Page 211: ...Index C 1 Festo P BE VTSA 44 EN en 1101f Appendix C Index ...
Page 212: ...C Index C 2 Festo P BE VTSA 44 EN en 1101f Contents C Stichwortverzeichnis C 1 ...
Page 220: ...C Index C 10 Festo P BE VTSA 44 EN en 1101f ...