1. Summary of components
1-29
Festo P.BE-VTSA-44-EN en 1101f
position. When the valve is not switched, duct (1) of the valve
terminal is exhausted via the soft-start valve’s exhaust outlet.
The switching point for full operating pressure is set to 4 bar
at the factory, but can be changed using an adjusting screw.
The piston position of the soft-start valve can optionally be
monitored by an inductive sensor (N/O contact). This sensor
registers whether the valve has switched and therefore
whether the valve terminal is being supplied with air. Due to
the required calibration, the later addition of the sensor by
the customer is not intended. A pressure gauge is optionally
available as a pressure indicator.
Note
– The VTSA valve terminal can be equipped with a
maximum of 5 soft-start valves.
– If a soft-start valve is used in the VTSA valve terminal,
no additional pressure-supplying components may be
used in the same pressure zone.
– Exhaust air cannot be expelled via the soft-start valve.
If a pressure zone is operated with a separate duct (1)
and 3/5 duct, an exhaust plate is required in this
pressure zone.
– Instructions for combining the soft-start valve, pneu-
matic supply plate and the right end plate can be found
in the VABV-S6-1Q-... assembly instructions.
Control block
The control block type
VOFA-B26-T52-M-...
(ident. code SP or
SN) is intended for two-channel control of pneumatic drive
components (e.g. double-acting linear cylinders) and can be
used for implementing the following protective measures:
–
Protection against unexpected starting up (EN 1037)
–
Reversing of dangerous movements if no further dangers
can occur through the reversing movements
Summary of Contents for VTSA-44-ASI Series
Page 2: ......
Page 16: ...Contents and general instructions XIV Festo P BE VTSA 44 EN en 1101f ...
Page 17: ...Summary of components 1 1 Festo P BE VTSA 44 EN en 1101f Chapter 1 Summary of components ...
Page 63: ...Fitting 2 1 Festo P BE VTSA 44 EN en 1101f Chapter 2 Fitting ...
Page 79: ...Installation 3 1 Festo P BE VTSA 44 EN en 1101f Chapter 3 Installation ...
Page 89: ...3 Installation 3 11 Festo P BE VTSA 44 EN en 1101f 1 2 4 3 Fig 3 2 Removing the tubing ...
Page 125: ...Commissioning 4 1 Festo P BE VTSA 44 EN en 1101f Chapter 4 Commissioning ...
Page 142: ...4 Commissioning 4 18 Festo P BE VTSA 44 EN en 1101f ...
Page 167: ...Technical appendix A 1 Festo P BE VTSA 44 EN en 1101f Appendix A Technical appendix ...
Page 210: ...B Supplementary component summary B 18 Festo P BE VTSA 44 EN en 1101f ...
Page 211: ...Index C 1 Festo P BE VTSA 44 EN en 1101f Appendix C Index ...
Page 212: ...C Index C 2 Festo P BE VTSA 44 EN en 1101f Contents C Stichwortverzeichnis C 1 ...
Page 220: ...C Index C 10 Festo P BE VTSA 44 EN en 1101f ...