A. Technical appendix
A-4
Festo P.BE-CTEU-CO-OP+MAINT-EN en 1101NH
General
Materials
– Housing
– Fibre-optic, cover DIL switch
– Threaded sleeve M12
– Threaded bush M3
– Seals
– Screws
RoHS-compliant
PA, reinforced
PC
Brass, electro nickel-plated
Brass
NBR
Galvanized steel
Corrosion protection
CRC 2
Voltage supply
Operating voltage
1)
– Nominal value
– Tolerance
24 V DC
18 … 30 V DC
Load voltage
1)
of connected devices
– Range
18 … 30 V DC
2)
Current supply
– Power rating for operating and load voltage
(residual current)
– Intrinsic current consumption of the bus node
(at 24 V DC)
– Current consumption (at 24 V DC) of the bus
node with operation of a connected device
– Current consumption (at 24 V DC) of the bus
node with operation of one/two connected
devices via electric sub-base CAPC-…
Max. 4 A
Max. 65 mA
Max. 120 mA
Max. 175 mA
Galvanic isolation
Bus interface
1)
External fuse required
2)
Dependent on the connected device (e. g. valve terminal)
Summary of Contents for CTEU-CO
Page 2: ......
Page 14: ...Installation XII Festo P BE CTEU CO OP MAINT EN en 1101NH ...
Page 15: ...Commissioning 1 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Chapter 1 Commissioning ...
Page 37: ...Diagnosis 2 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Chapter 2 Diagnosis ...
Page 51: ...Error treatment 3 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Chapter 3 Error treatment ...
Page 58: ...3 Error treatment 3 8 Festo P BE CTEU CO OP MAINT EN en 1101NH ...
Page 59: ...Technical appendix A 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Appendix A Technical appendix ...
Page 74: ...A Technical appendix A 16 Festo P BE CTEU CO OP MAINT EN en 1101NH ...
Page 75: ...Index B 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Appendix B Index ...
Page 76: ...B Index B 2 Festo P BE CTEU CO OP MAINT EN en 1101NH Contents B Index B 1 ...